BPQDY - 8341, PROTURF FERTILIZER WITH MINORS 26-4-1
- MSDS: BPQDY
- Manufacturer: O M SCOTT AND SONS CO
- Product Name: 8341, PROTURF FERTILIZER WITH MINORS 26-4-1
- National Stock Number: 8720-00N033240
Product Identification
Product ID:8341, PROTURF FERTILIZER WITH MINORS 26-4-1
MSDS Date:11/11/1988
FSC:8720
NIIN:00N033240
MSDS Number: BPQDY
Responsible Party
MARYSVILLE, OH 43041
US
Emergency Phone: 513-644-0011
Info Phone: 513-644-0011
Cage: FO079
Contractor
Telephone: 513-644-0011
Cage: 6K952
Ingredients
AMMONIUM DIHYDROGEN PHOSPHATE; (MONOAMMONIUM PHOSPHATE)
CAS: 7722-76-1
UREA
CAS: 57-13-6
RTECS: YR6250000
POTASSIUM SULFATE
CAS: 7778-80-5
RTECS: TT5900000
1), HEPTAHYDRATE; (FERROUS SULFATE)
CAS: 7782-63-0
RTECS: NO8510000
ACGIH TLV: 1 MG/M3 (MFR)
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
1) (SARA III)
CAS: 7733-02-0
RTECS: ZH5260000
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
ZINC OXIDE
CAS: 1314-13-2
RTECS: ZH4810000
OSHA PEL 15MG/M3 TDUST/5 FUME
ACGIH TLV: 10MG/M3 TDUST; 9293
MANGANESE; (MANGANESE SULFATE) (SARA III)
CAS: 7439-96-5
RTECS: OO9275000
OSHA PEL (C) 5 MG/M3 DUST
ACGIH TLV: 5 MG/M3 DUST 9293
MANGANESE (II) OXIDE; (MANGANESE OXIDE)
CAS: 1344-43-0
RTECS: OP0900000
OSHA PEL 5 MG/M3, C
ACGIH TLV: 5 MG/M3 DUST (MN)
1317-38-0)
CAS: 1317-39-1
RTECS: GL8050000
OSHA PEL 0.1 MG/M3 (CU FUME)
ACGIH TLV: 1 MG/M3 (CU DUST)
MOLYBDIC ACID, DISODIUM SALT; (SODIUM MOLYBDATE (VI))
CAS: 7631-95-0
RTECS: QA5075000
OSHA PEL 5 MG/M3;10 DUST (MO)
ACGIH TLV: 5 MG/M3 (MO)
MAGNESIUM (II), SULFATE, HEPTAHYDRATE; (MAGNESIUM SULFATE)
CAS: 7487-88-9
RTECS: OM4500000
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE/CHRONIC: MAY CAUSE EYE
IRRITATION. POSSIBLE NAUSEA, VOMITING & DIARRHEA. POSSIBLE SKIN OR
EYE IRRITATION.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INGEST:INDUCE VOMITING OR GASTRIC LAVAGE IF LARGE AMOUNTS
INGESTED. TREAT SYMPTOMATIC & SUPPORTIVE. SKIN:WASH EXPOSED AREAS.
EYES:FLUSH W/WATER FOR AT LEAST 15 MINS. IF IRRITATION PERSISTS,
SEE MD. IN HAL:REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE
O*2/ARTF RESP) .
Fire Fighting
Extinguishing Media:DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE KNOWN.
Accidental Release
Spill Release Procedures:SWEEP UP SPILLS. USE GOOD HOUSEKEEPING
PRACTICES. AVOID CONTACT W/SKIN, EYES OR CLOTHING. WASH AFTER
HANDLING.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:SEE LABEL. AVOID BAG BREAKAGE. KEEP
AWAY FROM FEED OR FOODSTUFFS. AVOID CONTACT W/SKIN, EYES OR
CLOTHING. KEEP OUT OF LAKES, STREAMS OR PONDS.
Other Precautions:KEEP OUT OF REACH OF CHILDREN.
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:NOT APPLICABLE.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NOT APPLICABLE.
Work Hygienic Practices:WASH AFTER HANDLING.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
Chemical Properties
Appearance and Odor:GRANULAR.
Stability
Stability Indicator/Materials to Avoid:YES
NOT APPLICABLE.
Stability Condition to Avoid:NOT APPLICABLE.
Hazardous Decomposition Products:UREA & METHYLENE UREA NITROGEN SOURCES
CAN GENERATE AMMONIA IN A FIRE.
Disposal
Waste Disposal Methods:REMOVE TO APPROVED LANDFILL. DISPOSAL MUST BE IN
ACCORDANCE W/FEDERAL, STATE & LOCAL REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their